top of page

Data Centre Wall Systems · UK Supply & Installation

IMPACTPRO® Data Centre Wall Systems

Durable PVC-u wall cladding for data centres, server rooms and supporting technical areas, planned around services, openings and the project specification.

Impact Group UK can review drawings, room heights, openings, services and wall-finish schedules before quotation so sheet layouts, details and installation requirements are coordinated around the actual space.

Request a data centre wall-cladding quotation

Data centre wall cladding for demanding technical environments

Different rooms within a data-centre facility have different requirements. IMPACTPRO is intended as a bonded internal PVC-u finish only in areas where the approved project specification permits it and where relevant fire, electrical, security and operational requirements have been resolved.

Data Hall and Ancillary Wall Areas

Perimeter and ancillary wall areas where the approved internal finish specification permits PVC-u cladding.

Server, Comms and Technical Rooms

Server room wall cladding can provide a cleanable internal finish around technical equipment, doors, service routes and wall-mounted infrastructure.

Plant and Support Areas

Durable internal finishes for frequently accessed support spaces where a wipe-clean wall surface is required.

UPS and Electrical Support Areas

Wall finishing for selected electrical-support spaces only where the electrical and fire requirements allow the proposed finish.

Corridors and Service Routes

Hard-wearing wall finishes for high-use circulation and back-of-house routes exposed to everyday wear.

Control Rooms and Support Spaces

Durable internal wall finishes for operational, technical-support and ancillary areas within data-centre facilities.

Why specify PVC-u wall cladding in suitable data-centre areas?

Where the approved project design permits a bonded PVC-u finish, IMPACTPRO provides a durable, cleanable internal lining with large-format sheet planning, project-specific detailing and UK-wide supply and specialist installation support.

IMPACTPRO does not replace fire-rated compartment walls or passive fire protection, ESD-control systems, security-rated construction, the acoustic, thermal or airtightness performance of the wall build-up, fire suppression, cooling or other data-centre engineering systems.

Specification boundary: fire strategy, substrate, electrical requirements, ESD control, security, acoustic performance, thermal performance and specialist services must be resolved by the relevant project designers and systems. IMPACTPRO is the internal wall finish where the approved design permits its use.

Plan the wall around the room — not the other way around

Large-format sheet planning matters in technical spaces because doors, windows, containment routes, service penetrations and wall-mounted equipment can quickly turn a simple wall into a complex installation.

IMPACTPRO project formats are based around 1220 mm sheet widths. Typical sheet heights across the range can include 2440, 2800 and 3050 mm, subject to the selected finish and current product availability.

Doors and windows should be checked against the vertical sheet set-out. Where suitable, a joint can align with an opening jamb rather than crossing the opening. Sockets and service penetrations should be kept clear of vertical sheet joints where practicable, with the sheet start position adjusted before cutting.

  • 1220 mm sheet width.
  • Typical project heights can include 2440, 2800 and 3050 mm, subject to selected finish and availability.
  • Profile or welded detailing may be available depending on the selected IMPACTPRO finish and project specification.
  • Fully bonded installation to a suitable substrate.

Coordinate the interfaces before installation starts

Doors, frames, services, corners and floor or ceiling junctions are where otherwise simple sheet layouts become complex. Impact Group UK can review these interfaces before fitting begins.

Doors, Windows and Frames

Door and window positions should be checked against the sheet set-out so a vertical joint does not run through the opening. Where suitable, the joint can be aligned to a jamb and the remaining cuts planned around the frame detail.

Service Penetrations

Cable routes, conduits, sockets and wall penetrations need agreed positions before the sheet layout is finalised. Where practicable, the set-out should keep these service features clear of vertical sheet joints.

Internal Corners

Corner strategy can use the selected system's approved profile or formed detail, depending on product, geometry and specification.

External Corners

Exposed corners are vulnerable to damage and should be coordinated with the intended wall-protection strategy where required.

Floor and Ceiling Interfaces

Top and bottom terminations should follow the approved wall build-up, floor finish, skirting or coving and ceiling interface.

Wall Protection Interfaces

Where circulation or service routes need additional impact protection, the wall-cladding and protection package can be coordinated together.

Send the drawings and schedules needed for an accurate quotation

For a project-specific data centre wall-cladding quotation, provide the available project information including:

  • GA plans and room layouts.
  • Wall elevations, heights and openings.
  • Room data and technical constraints.
  • Wall-finish schedules and product requirements.
  • Applicable fire, ESD, electrical and specialist-system information relevant to the finish.
  • Programme, access and phasing information.

Send project drawings · View site survey service

From project drawings to an installed wall finish

  1. Review plans, elevations, room data and the wall-finish specification.
  2. Take off wall areas, heights, openings and project-specific quantities.
  3. Plan sheet orientation, joints and practical material layout.
  4. Coordinate corners, doors, penetrations, terminations and wall-protection interfaces.
  5. Issue a clear project-specific supply and installation quotation.
  6. Plan nationwide supply and specialist installation.

Technical routes for a buildable data centre wall-cladding specification

IMPACTPRO White · Fire Performance Guidance · Technical Resources · Quantum Computing & Silicon Labs

Questions project teams ask before specifying data centre wall cladding

What wall finishes can be used in a data centre?

The answer depends on the room, fire strategy, electrical/ESD requirements, security requirements and the wider wall build-up. PVC-u wall cladding can be considered as an internal finished lining in areas where the approved project specification permits it.

Can PVC-u wall cladding be used in server rooms?

It can be suitable as an internal wall finish in selected server or technical rooms where the project designers have confirmed that the material, substrate, fire strategy, electrical requirements and operational conditions are appropriate.

Is IMPACTPRO a fire-rated compartment wall system?

No. IMPACTPRO is an internal wall-cladding finish. It does not replace fire-rated walls, cavity barriers, fire stopping or other passive fire-protection systems. The complete construction must follow the project's approved fire strategy and specification.

Is IMPACTPRO an ESD wall system?

IMPACTPRO should not be presented as a specialist ESD-control system unless a specific approved product specification states otherwise. Any ESD requirement for a data-centre space must be designed and verified separately.

Can PVC-u wall cladding be installed around services and penetrations?

Yes. Doors, windows and service penetrations can be incorporated into the sheet layout, but the set-out should be checked before cutting. Where suitable, vertical joints can align with opening jambs rather than crossing the opening, while sockets and service penetrations should be kept clear of vertical joints where practicable. Fire stopping and specialist service sealing remain separate project requirements.

What IMPACTPRO sheet sizes are available?

IMPACTPRO project formats are based around 1220 mm sheet widths. Typical heights across the range can include 2440, 2800 and 3050 mm, subject to selected finish and current availability. Final sizes should be confirmed when the project is quoted.

Can Impact Group UK price data-centre wall cladding from drawings?

Yes. Send plans, elevations, room data, wall-finish schedules and the relevant specification information. Impact Group UK can review the scope and prepare a project-specific quotation.

Do you install data-centre wall cladding nationwide?

Impact Group UK provides commercial wall-cladding supply and specialist installation support across the United Kingdom, subject to project scope, programme and site requirements.

Send the drawings. We will build the wall-cladding scope around the project.

Speak to Impact Group UK about IMPACTPRO wall cladding, technical detailing, nationwide supply and professional installation for data-centre and technical environments.

Request a quotation · Technical resources

bottom of page